      1. Specifications:

      Model     voltage    power    frequency     output    ice storage   refrigerant     input

      ZB-20B  220V-240V   200W   50Hz-60Hz   20Kg/24h    8KG       R134        250g

      ZB-25   220V-240V   290W   50Hz-60Hz   25Kg/24h    10Kg       R134        300g

      ZB-45   220V-240V   380W   50Hz-60Hz   45Kg/24h    20Kg       R134        350g

      ZB-60   220V-240V   480W   50Hz-60Hz   60Kg/24h    35Kg       R134        420g

      ZB-90   220V-240V   650W   50Hz-60Hz   90Kg/24h    45Kg       R134        800g

      ZB-120  220V-240V   700W   50Hz-60Hz   120Kg/24h   45Kg       R134        800g

      ZB-150  220V-240V   760W   50Hz-60Hz   150Kg/24h   100Kg      R134/404a   1000g

      ZB-250  220V-240V   1080W  50Hz-60Hz   250Kg/24h   100Kg      R134/404a   1200g

      ZB-350  220V-240V   1285W  50Hz-60Hz   350Kg/24h   190Kg      R134/404a   1500g

      ZB-500  220V-240V   1500W  50Hz-60Hz   500Kg/24h   190Kg      R134/404a   1600g

      ZB-700  380V-420V   2300W  50Hz-60Hz   700Kg/24h   350KG      R134/404a   1800g

      2. Working conditions:

                                 Minimum                  Maximum

      Environmental temperature       10                       40

      Water temperature               5                       40

      Water pressure              1 bar (0.1 MPa)              5bar (0.5MPa)

      Rated voltage difference        220V+ 10%

      3. Installation:

      (1) The location for the machine should be equipped with the following devices:

      a. power of 220V/50Hz-60Hz

      b. water resource and switch

      c. pipeline for water drainage

      (2) The machine should be put in level to keep the ice producing effort and prevent from the vibration.

      (3) The machine has to be put in the good ventilation location, it should kept away 150mm from the other objects for 

      the air exchangeThe machine should be kept away from other heating resources, such as heaters and

       ovens etc. The machine should be equipped with suitable power switch, fuse and breaker (model: DZ12L-60G/1N, the rated breaking current is 15mA, the non- breaking current is 7.5mA). The current volume

       for the socket and cable is not less than 10A. The socket must have qualified earthling wire.

      (4) If the water quality is not so good, you should connect a filter to the tap. The water quality for 

      the ice producing should meet the drinking standards.

      4. Transportation and storage

      In transportation, it should be very careful, prevention from heavy vibration. The machine in package cannot be put in open-air for long time. It should be put in the good facility of air and non-corrosive air storage. It cannot be put upside-down. If it is necessary to put it in open-air, it should have waterproof facilities. 

      5. Operation

      (1) The appliance is equipped with temperature and time control system. The process is completed automatically from water in to ice out. It is no need man power, so it is simple and convenient in operation. What you have to do is only turning on the power and water.

      (2) During the operation, when the cabinet is full of ice cubes, the machine will stop automatically. You should take out some of ice cubes and the machine will start again.

      (3) You should connect water pipe for the machine. The water pressure should be between 0.1-0.5MPa. The flow can be adjusted by the tap and it depends on the drainage volume of frost-melting. If the drainage is big, turn up the tap, if the drainage is small, turn down the tap.

      (4) The silicon balls inside the machine are for prevention of the internal bottom from striking of the ice falling down. So, the silicon balls have to be put in the operation and taken out for cleaning regularly.

      6. Maintenance and cleaning

      (1) Before maintenance or cleaning, you must turn off the power and water.

      (2) Keep clean for the machine and clean it regularly. You can clean it with non corrosive detergent first and dry it with cleaner. It is forbidden to water it directly or cleaning it with acid, alkali, alcohol, or gasoline.

      (3) Taking off the curtain first and clean the refrigerator with duster, brush and metal brush. But be careful for the radiators.

      (4) You should make cleaning after operation. If the machine will not be used for a long time, you should clean the machine and dry it and keep it well.

      (5) The machine will be in good operation life if you make good maintenance and daily cleaning.

      7. Refrigerating system diagram:

       

      8. Electricity diagram:

       

       

       1.Ice producing (temperature) controller------------

       2. Frost melting (temperature) controller--------------

       3.  Frost melting time controller-------------------------

       4.  Power----------------------------------------------------

       5.  Earthling------------------------------------------------

       6.  Compressor---------------------------------------------

       7.  Fan-------------------------------------------------------

       8.  Pump-----------------------------------------------------

       9.  Solenoid valve------------------------------------------

       10. water valve-----------------------------------------------

       

       

      9Troubles and treatments

       

      Troubles            Causes                            Treatments

      No running          1. no power or power wire not fixed   1. check the power and power wire

                         2. ice producing thermostatic burnt     2. replace the thermostatic

                           out

      Compressor doesnt

      work        ,       1. voltage is low or heat protector    1. check the power voltage and heat

                           burnt out                        protector

                         2. the wire of compressor starter loose  2. check and fix the wire

                         3. compressor breaks down           3. replace compressor

                         4. capacitor of compressor burnt out    4. replace the capacitor

                         5. refrigerating thermostatic is in bad   5. replace the thermostatic 

                           connection                    

      No water in trough    1. the tap is turned off              1. turn on the tap

                         2. the water tank leaks              2. sealing the leakage

                         3. the inlet solenoid is blocked      3. replace the solenoid or clean the

                           or broken down                 pipeline

      The trough flows

      over              1. water pressure is over            1. turn down the tap

                        2. the over flow pipe is blocked       2. check and repair the pipe

                        3. the inlet solenoid breaks down      3. replace the solenoid

      The refrigerator is   1. the fan breaks down               1. replace the fan

      over heat and the   2. the piping is blocked             2. check the piping and vacuate it   

      refrigerating is not                                   and fill with Freon

      good    

      Water pump doesnt

      run              1. the blades of fan is blocked or     1. check the fan or replace the pump

                          moter breaks down  

                        2. the pipeline contains air          2. let water enter into the trough and

                                                         restart the machine to put out of the air

                        3. no power to water pump         3. check the wire to see if the time for frost melting is too long

      The ice is too     1. the refrigerating controller is       1. set the controller counter clock-wise

      thin              not set well

                        2. the refrigerant leaks             2. check the leakage and refill Freon

                        3. the refrigerator fan doesnt run    3. check the fan

                        4. the piping is blocked            4. check out the blockage and

      re-vacuate it and fill with Freon

                        5. lack of water                  5. refer to the solutions of lack of water

                        6. the refrigerator is dirty          6. clean the radiators of refrigerator

      Ice is unclear       1. the water is not clean            1. connect water filter

                        2. impurity accumulates            2.drain the water with impurity

      Big noise          1. the machine is put unstable        1. put it stably 

                        2. the fixing bolts are loose         2. check the bolts and fasten again

      The ice not fall

      down            1. the ice doesnt form cube           1. check the refrigerator

                       2. the machine is not put horizontally    2. adjust the machine

                       3. the time relay is not adjusted right   3. adjust the time relay to 1-2min.

       

      10. Notes

      (1) You must connect the power base on the indication of nameplateThe capacity of power wire 

         and socket must meet the national standards. The manufacturer will not guarantee for the

      operation in wrong voltage.

      (2) you must connect earthling wire.

      (3) The water pressure cannot be too big, it should be less than 0.5MPa.

      (4) In transportation, the angle of inclination cannot be beyond 45° to prevent the compressor from damage.

      (5) It is forbidden to put water inside or outside of the  machine to avoid causing leaking of electricity or accidences.

      (6) The operator must not put the hands into compressor or refrigerator.

       

      Accessories:

      1. inlet pipe 1pc.

      2. outlet pipe 1pc.

      3. Silicon piece 1pc.        

           